# Arc discharge pump (ADP)

> Original page (HTML): https://vaclab.ru/devices/arc-vacuum-pump
> Markdown version: https://vaclab.ru/devices/arc-vacuum-pump.md
> Manufacturer: LLC "Laboratory of Vacuum Technologies Plus" (LVT), vaclab.ru

Arc-discharge pump (ADP) - a high-performance unit for gas pumping and creating high vacuum in industrial technological installations for vacuum metallization, electron beam welding, and vacuum furnaces.

Purpose:

- 
Obtaining "dry" vacuum in technological installations

- 
High-performance pumping of any chemically active gases

Operating principle:

- 
Pumped gases are absorbed by a titanium getter layer deposited on the cooled walls of the pump chamber

- 
Titanium evaporates from a cathode located in the center of the chamber using a vacuum arc

- 
The arc initiation and extinction are controlled by a controller that maintains a preset evaporation rate

- 
The evaporation rate can be adjusted based on feedback from a vacuum gauge, automatically maintaining pumping performance without excessive cathode consumption

- 
An auxiliary diffusion or turbomolecular pump provides initial vacuum and pumping of the inert component of residual gases

Advantages:

- 
Stable high pumping speed over a wide pressure range

- 
Does not require high-performance forevacuum pumping

- 
Ability to manufacture pumps of any performance

- 
Can pump aggressive gases, such as chlorides

- 
Not affected by condensation of liquid or solid deposits, can be used for pumping organic vapor

- 
Not damaged by atmospheric or water breakthrough

- 
Does not require time for start-up and shutdown

Operating features:

- 
Periodic maintenance - cleaning the pump chamber - takes no more than 30 minutes

- 
Cathode life, depending on operating conditions, ranges from one to three years

- 
Automatic monitoring of cathode condition and the need for wall cleaning

Application recommendations:

- 
Vacuum pumping of large-volume chambers

- 
Technological processes associated with strong gas emission

- 
Pumping of aggressive gases, such as chlorides

## Technical specifications

- Dimensions *(Length x Width x Height),  mm, not more than: 1219 х 816 х 1960
- Pumping rate: 20 000 (по азоту)
- Weight, kg: 650
- Mounting flange: ISO400
- Power consumption, W: 15 000